Features 2
Bluelab pH Meter 2
Introduction 3
Preparing for use 3
Calibration 4
Measuring the pH value 6
Battery replacement 6
Cleaning the pH Probe 7
Hydrating the pH probe 8
Storing the Bluelab pH Meter 8
Error messages 9
Technical speci cation 9
Troubleshooting guide 10
Bluelab pH Probe
replacement 11
Bluelab pH Probe care 11
Product guarantee 12
Limitation of liability 12
Contact details 12
Care and use guide
Zobrazit stránku 0
1 2 3 4 5 6 ... 11 12

Shrnutí obsahu

Strany 1 - Care and use guide

Contents pageFeatures 2Bluelab pH Meter 2Introduction 3Preparing for use 3Calibration 4Measuring the pH value 6Battery replacement 6Cleaning the

Strany 2 - Bluelab pH Meter

English1011.0 Troubleshooting guideTrouble Reason CorrectionpH reading inaccurateContaminated pH probe / glassware not clean.Clean pH probe (see secti

Strany 3 - 2.0 Preparing for use

English11Bluelab Probe Care - pHThe instrument is only as accurate as the probe is clean!Bluelab pH Probe KCl Storage SolutionThe perfect solution to

Strany 4 - 3.0 Calibration

English12Bluelab pH Meter product guaranteeBluelab Corporation Limited guarantees this product for a period of5 years (60 months) from the date of sa

Strany 5 - 3.0 Calibration cont

English2FeaturesLightweight and portable Over range and under range indicatorsLarge easy to read display 2 x AAA alkaline batteries includedSimple pus

Strany 6 - 4.0 Measuring the pH value

English31.0 Introduction to the Bluelab pH MeterThe Bluelab pH Meter has two press buttons; ‘calibrate’ and power. The power button requires a short

Strany 7

English43.0 CalibrationpH calibration is required before fi rst use and then monthly to ensure readings are accurate.For accurate pH readings the pH

Strany 8 - 7.0 Hydrating the pH probe

English53.0 Calibration cont.To calibrate the pHClean pH probe tip.See section 6.0 (the pH probe does not require cleaning before the fi rst use).pH

Strany 9 - 10.0 Technical speci cations

English65.0 Battery replacementBatteries are replaced in the Bluelab pH Meter when the low battery indicator appears on screen.The low battery indicat

Strany 10 - 11.0 Troubleshooting guide

English76.0 Cleaning the Bluelab pH ProbeTo ensure accurate readings the pH probe tip needs to be rinsed in water after each use and cleaned prior to

Strany 11 - Bluelab pH Probe replacement

English88.0 Storing the Bluelab pH MeterStore the pH Meter in a cool, dry and clean place when not in use.Keep out of direct sunlight.Keep pH Meter o

Strany 12 - Limitation of Liability

English99.0 Error messagesAn error message will only appear following pH calibration failure.‘Err’ will be displayed for a few seconds then the displa